3 ½ Digit LCD Digital Panel Meter. PM / P Lux Meter. dB. Meter. LCR Meter. Watt Meter. Other industrial & dom estic uses PMA (Independent Pow. LED Digital Panel Meter – 9V Independent Ground Features: mV full scale input sensitivity Single DC operation Decimal point selectable ” figure height . Superior Customer Service. Circuit Specialists strives to provide the highest level of customer service. Our knowledgeable tech support staff will try to help you in.

Author: Kazrara Muzilkree
Country: Zambia
Language: English (Spanish)
Genre: Relationship
Published (Last): 5 August 2017
Pages: 83
PDF File Size: 12.10 Mb
ePub File Size: 15.53 Mb
ISBN: 561-5-64961-193-5
Downloads: 51182
Price: Free* [*Free Regsitration Required]
Uploader: Nigami

PMA led panel meter problem. It is showing at the first digit a “-1” and the other digits do not light at all, accept the decimal point. The meter is set up for mV input measurement. After connecting the V- of the input channel to the gnd of the power suplly this error was showing up.

No input is red any more. Afterwarts reading the manual I discouvered that the meter should have a independent powersupply.:???: It is not clear in the manual if i only can read independent inputs or that i must read indepent inputs. Are my strongest fears becumming true?:???: Did i blow up the fets of the input and is the CPL chip blown up, or is there some thing else wrong?: PMA led panel meter problem It clearly says that this is a single 9 Volts supply version of the meter.

Means it needs separate 9 Volts supply to operate the meter and the you can measure the input. Did you read the manual before connecting it? Now make clear that when you connect the 9 volts supply does the meter display -1 and stays on with other digits blank? After your response further guidance may continued. PMA led panel meter problem Yes I have red the manual before, but it was not clear that it was not possible to connect the input to the gnd of the power supply.

  HVR 062 DATASHEET PDF

Connecting it with a 9 Volt battery and the meter displays again -1 and the ohter digits stay blank.

PMA led panel meter problem This shows over ranged input the -1which will cause the other digits to stay blank. It may have spoiled the input circuit. If you can check the circuit, then try to locate the circuit on PIN numbers 30 and See if there is any resistance divider or any other circuit apparently look bad. And if you have some experience on Diagram reading and following I can send you the circuit duly marked for check points. PMA led panel meter problem Great!

I can read diagrams. So if you point out where the problem is, then it will help me to clearify the problem.

PMA led panel meter problem Ok here is a reference circuit for you. Pin 30 measures 0V. When give a reverse input, pin 30 measures 92 mV and pin 31 0 V. What can you conclude? While you connect 92 mV or so on input digihal, can you measure voltage on Pin It digitall read minus voltage estimated -5 V and if this is true then I am afraid that is gone defective.

Voltcraft PM 129 LED Digital Panel Meter

If you short circuit the input terminals going to pin 30 and pin 31 the reading must be zero and if this does not go to zero it meas there is some internal fault developed in Originally Posted by Raza. PMA led panel meter problem OK but better to be sure that there is no culprit on the existing board which may cause any problem for the new chip.

  BUILDING FINDABLE WEBSITES WEB STANDARDS SEO AND BEYOND PDF

I tried a lot to get the circuit for PM but sorry no reference found. But the circuit for is same for any brand only differs on the input circuit. LED ;anel by RF was: LED with Solar Panel 5. Panel meter – DPM – spec wanted 2. Part and Inventory Search.

New 9V LED Panel Meter PMA – Digital Panel Meters | Circuit Specialists

AF modulator in Transmitter what is the A? What is the function of TR1 in this circuit 3. Losses in inductor of a boost converter 9. Turn on power triac – proposed circuit analysis 0. Choosing IC with EN signal 2. Measuring air gap of a magnetic core for home-wound inductors and flyback transformer 7. Hierarchical block is unconnected 3.

Digital emter appears to have measured voltages lower than expected.

PV charger battery circuit 4. How reliable is it?

Equating complex number interms of the other 6. CMOS Technology file 1.

Colluck Co. Ltd. – PMA, PMB Digital Panel Meters

ModelSim – How to force a struct type written in SystemVerilog? Input port and input output port declaration in top module 2. PNP transistor not working 2. Distorted Sine output from Transformer 8. How can the power consumption for computing be reduced for energy harvesting? Dec 242: How pxnel you get an MCU design to market quickly?

Dec 248: Heat sinks, Part 2: Synthesized tuning, Part 2: The time now is